DATA SHEET
HydraPort® 6 Module Connection Ports
HPX-600SL, Brushed Aluminum (FG560-01-SL)
HPX-600BL, Black Anodized (FG560-01-BL)
Overview
With space for up to six modules, the HPX-600 allows you to elegantly connect
mobile devices at your desk, lectern or table using the most beautiful connectivity
system ever developed. This sleek solution supports pass-through connectors for
audio, video, Ethernet, USB and power plus control. The modular assembly makes it
easy to change connections as needs evolve, and makes HydraPort
®
future proof for
connection types that have yet to be developed. The elegant, flush-mount design
conveniently opens in both directions providing a clean, unobtrusive look.
Common Applications
The HPX-600 is perfect for conference rooms, classrooms or auditoriums where users need a simple, convenient
way to connect devices power, Ethernet, USB, audio, and video.
Features
Modular Design is Future Proof Features an assembly with the flexibility to change the modules to meet
current and future needs
Variety of Sizes for All Types of Applications The HPX-600 accommodates six module units. Use the
HydraPort Connection Preview Application to determine the size needed, based on the connection modules
desired
Elegant and Unobtrusive Flush-mount design installs cleanly into a lectern or table and the lid conveniently
opens in both directions providing a clean look
No Electrician Required HydraPort power modules can be connected directly to a wall or floor outlet
eliminating the need for an electrician
Control The Room Add Metreau
®
or Novara
®
Keypad modules to control AV devices, lighting or shades as
well as to initiate pre-programmed events
Anodized Aluminum These stylish, low profile connectivity ports have the same contemporary brushed
aluminum enclosure as the higher-end office furniture manufacturers at the same price as most competitive
painted metal models
Seitenansicht 0
1 2 3 4 5 6 ... 16 17

Inhaltsverzeichnis

Seite 1

© 2014 AMX. All rights reserved. DATA SHEET HydraPort® 6 Module Connection Ports HPX-600SL, Brushed Aluminum (FG560-01-SL) HP

Seite 2

10 sight in a HydraPort HPX-600, 900 or 1200 chassis. DIMENSIONS 3 HydraPort Units HPX-U100-BTN (FG554-01) Single Button Module with LED OVERVIEW

Seite 3 - MODULES

11 indicators that illuminate when pressed to confirm the source/function was selected and that it is currently being used. These pre-printed buttons

Seite 4

12 FEATURES ° AxLink connectivity to NetLinx master ° Standard buttons include 1-9, 0, ENTER, SAVE, and +/- ° Blue LEDs glow to indicate button

Seite 5

13 for channel adjustments REAR PANEL COMPONENTS DIP switch – 8 position mini DIP switch used to set the device address for the keypad on the AxLin

Seite 6

14 FRONT PANEL COMPONENTS 13 tactile pushbuttons with blue LED indicators that illuminate when pressed to confirm the source/function was selected a

Seite 7

15 ° 4-pin AxLink connector and Status LED ° Blue, backlit buttons with controllable feedback ° Includes acetate sheet with 50 pre-cut button la

Seite 8

16 REAR PANEL COMPONENTS IEC 60320 C13 power cord connector HPX-P200-PC-AU (FG561-31) Power Outlet (AU) Module OVERVIEW The HPX-P200-PC-AU module

Seite 9

17 HPX-B100-L (FG558-12) 1 M Custom Label Panel OVERVIEW The HPX-B100-L is a blank panel that is pad printed with custom text, and is available for

Seite 10

2  Updated Web HydraPort Connection Preview Application – Now you can select from all four connection port bases and even switch from one to the ot

Seite 11

3 HPX-600 COMPATIBLE HYDRAPORT CONNECTION MODULES HPX-AV101-HDMI-R (FG552-27) Single HDMI Module with Retractable Cable OVERVIEW The HydraPort HDM

Seite 12

4 1 1/2 HydraPort Units Under Table Enclosure Volume: 20 in3 WEIGHT Approximately 1lb (0.46 Kg) INTEGRATED CABLE •DisplayPort to HDMI Retractabl

Seite 13

5 •No Assembly, Adjustments or Terminations – Installs quickly and easily with no special mounting DIMENSIONS 1 1/2 HydraPort Units Under Table En

Seite 14

6 REAR PANEL COMPONENTS 6’ 6 3/4” (2 m) Cable to male DVI-D connector 6’ 6 3/4” (2 m) Cable to male 1/8” stereo mini-jack audio connector HPX-AV100-C

Seite 15

7 FRONT PANEL COMPONENTS 3 female RCA connectors (1 for video, 2 for right/left audio) REAR PANEL COMPONENTS RJ-45 connector for UDM Cat5 HPX-C540

Seite 16

8 HPX-N102-RJ45 (FG553-02) Dual Ethernet Module OVERVIEW The HPX-N102-RJ45 module provides two RJ-45 connections to the HydraPort chassis. DIMENSIO

Seite 17 - About AMX

9 module to the USB Ports on the PSU2.1 USB Power Supply INCLUDED ACCESSORIES PSU2.1 USB Power Supply (FG423-25) SPECIFICATIONS FOR PSU2.1 POWER SU