Installer/User GuideAMX™ Series
4 AMX Series Installer/User GuideSharingIf two or more users need access to the same server or serial device, they can share access through the AMX S
Chapter 1: Product Overview 5• Avocent matrix intelligent module(s) (AMIQ or AMIQ-SRL)• UTP cablesThe quantity and type of components you receive
6 AMX Series Installer/User Guide64 Servers AMX5110 User Station AMX5010 Switch 16 Users AMIQ Module UTP CablesFigure 1.2: Typical AMX ConfigurationT
Chapter 1: Product Overview 7 identifies the attached server within the system. The connection between the AMX system and these modules is throug
8 AMX Series Installer/User GuideRack mount safety considerations• Elevated Ambient Temperature: If installed in a closed rack assembly, the operati
Contents2InstallationGetting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Installing an AMX System . . . . . . . . . . . . .
Chapter 2: Installation 11 Chapter 2: InstallationThe AMX system uses standard UTP cables to transmit keyboard, video and mouse information betwe
12 AMX Series Installer/User GuideOptionally you may need:• AMWorks software available on the included CD and through download from AvocentInstallin
Chapter 2: Installation 13 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 6162 63 6449 50 51 52 53 54 55 56 57 58 59 60 61 62 63 649101112131415
INSTRUCTIONSThis symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literatur
14 AMX Series Installer/User GuideFigure 2.4: AMX5000 Rack Mounting DiagramFigure 2.5: AMX5010 Rack Mounting DiagramTo install the rack mounting brac
Chapter 2: Installation 15 To install a new single AMX switch:1. Plug the supplied power cord into the back of the AMX switch and then into an
16 AMX Series Installer/User GuideNetwork Port User Ports Server PortsNetwork Port User Ports Server PortsTerminal Port To make a LAN connection:Usin
Chapter 2: Installation 17 3. Connect one end of a UTP cable into the RJ-45 port on your AMIQ module. Route the cable to your AMX switch and con
18 AMX Series Installer/User GuideAC Power Connections toAMX Switch /Local ServerKVM Access Serial PortAC Power Connection to AMX Switch KVM AccessC
Chapter 2: Installation 19 4. Locate the power cord that shipped with the user station. Plug it into the power socket on the rear of the unit. P
20 AMX Series Installer/User GuideLocal Users AMX5110 AMX5010 AMX5000 AMX5000 AMX5000 AMX5000 Servers Servers Servers Servers AMX5000 AMX5000 Serve
Chapter 2: Installation 21 NOTE: If required, additional user stations can be placed on other layers of the AMX system. User rights and user info
22 AMX Series Installer/User Guide
Contents3Basic OperationsPower Up and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . 25User Operation . . . . . . . . . . . . . . . . . . . .
Avocent, the Avocent logo, AMX, AMWorks, OSCAR and The Power of Being There are trademarks or registered trademarks of Avocent Corporation or its affl
Chapter 3: Basic Operations 25 Chapter 3: Basic OperationsPower Up and LEDsAMX5000 or AMX5010There are three groups of LEDs on the front panel of
26 AMX Series Installer/User GuideThe rear panel of the AMX5110 and AMX5120 provides two LEDs, one green and one yellow, mounted on each UTP port con
Chapter 3: Basic Operations 27 If you have not logged in successfully, the OSD displays Matrix System and the names of locally connected computer
28 AMX Series Installer/User GuideTarget User ConsoleOSCARDual port behaviorAfter the AMX system is powered up, the connections made to the user stat
Chapter 3: Basic Operations 29 a server channel at the same time, but only one can enter data through the keyboard or mouse at any given moment.
30 AMX Series Installer/User GuideYou may choose to select an alternative OSD hotkey sequence by selecting one of the options listed in the pull-down
Chapter 3: Basic Operations 31 Selecting ServersUse the Target tab in the OSCAR dialog box to connect to servers. When you connect to a server, t
32 AMX Series Installer/User GuideTo set the scan dwell time:1. Press Ctrl+Ctrl to launch OSCAR.2. Click the User tab.Target User ConsoleOSCARUsernam
Chapter 3: Basic Operations 33 PS/2 Keyboard to Sun ComputerKey Sun Key SunF1 Stop F9 FindF2 Again F10 CutF3 Props F11 PowerF4 Undo F12 CommandF5
USA NotificationWarning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user&apos
34 AMX Series Installer/User Guide
Contents4Advanced OperationsUser Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Server Maintenance . . . . . . . . . . . . . . .
Chapter 4: Advanced Operations 37 Chapter 4: Advanced OperationsUser MaintenanceThe AMX system can be configured to support up to 128 users. Each
38 AMX Series Installer/User GuideFigure 4.2: Editing a User4. Click the username that you wish to edit, then click the Edit User button. Change th
Chapter 4: Advanced Operations 39 NOTE: The default setting for a user’s access rights is none.6. After confi guring all servers, click the OK butt
40 AMX Series Installer/User GuideNOTE: It is only possible to edit servers that are attached to the AMX system and powered.5. Enter the new name fo
Chapter 4: Advanced Operations 41 Figure 4.4: The Console Tab3. The current keyboard layout will be displayed. Click the double arrow to the righ
42 AMX Series Installer/User Guide4. Select your new sequence and click Apply. The selected sequence changes from blue to black text.To change the C
Chapter 4: Advanced Operations 43 Quick switch hotkey The quick switch hotkey enables you to connect to the next server on the list by selecting a
Table of ContentsChapter 1: Product OverviewFeatures and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3Component Overview . . . . . .
44 AMX Series Installer/User Guide
Contents5Terminal OperationsAccessing the Terminal Menu . . . . . . . . . . . . . . . . . 47
Chapter 5: Terminal Operations 47 Chapter 5: Terminal OperationsAccessing the Terminal MenuEach AMX5000 or AMX5010 can be configured at the unit
48 AMX Series Installer/User GuideSet the IDs of all AMX configurations that will be connected to the same subnet as shown in the following table. Co
ContentsAppendicesAppendix A: Technical Specifications . . . . . . . . . . . 51Appendix B: Using AMIQ-SRL Modules . . . . . . . . . 56Appendix C: Tech
Appendices 51 AppendicesAppendix A: Technical SpecificationsAMX5000 Product Specifi cationsServer Ports Number 32 Connectors RJ-45 AMX intercon
52 AMX Series Installer/User GuideAMX5010 Product Specifi cationsServer Ports Number 64 Connectors RJ-45 AMX interconnect User Ports Number 16
Appendices 53 AMX User Station (AMX5100, AMX5110, AMX5120) Product Specifi cationsServer Ports Number 1: AMX5100; 2: AMX5110 and AMX5120 Connec
54 AMX Series Installer/User GuideAMIQ Module Product Specifi cations Server Ports Number AMIQ-PS/2: 4; AMIQ-VSN: 2; AMIQ-WSN: 2 AMIQ-USB: 2 Type
Appendices 55 AMIQ-SRL Module Product Specifi cations Server Ports Number 1 Type DCE Connectors 9-pin D-sub female User Ports Number 1
56 AMX Series Installer/User GuideAppendix B: Using AMIQ-SRL ModulesThe AMIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devi
Appendices 57 mode, AMX and CD lines are turned off for one-half second and then turned on each time a module is selected or deselected. The defa
58 AMX Series Installer/User Guide• Clear History Key Sequence: This option allows you to defi ne the key com-bination that clears the history buffer
Appendices 59 Using History modeHistory mode allows you to examine the contents of the history buffer, which contains the events that have occurr
60 AMX Series Installer/User GuideAMIQ-SRL pinoutsThe AMIQ-SRL pinouts are provided in the following table.AMIQ-SRL Pinouts DB9-F Host Signal
Appendices 61 Appendix C: Technical SupportOur Technical Support staff is ready to assist you with any installation or operating issues you encou
62 AMX Series Installer/User Guide
Appendices 63
ContentsProduct Overview1Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3Component Overview . . . . . . . . . . . . . . . .
64 AMX Series Installer/User Guide
LIMITED WARRANTY Avocent Corporation warrants to the original retail purchaser that this product is and will be free from defects in materials and wor
590-222-001DFor Technical Support: Avocent Corporation4991 Corporate DriveHuntsville, Alabama 35805-6201 USATel: +1 256 430 4000 Fax: +1 256 430 4031A
Chapter 1: Product Overview 3 Chapter 1: Product OverviewFeatures and BenefitsThe Avocent AMX™ Series of products allows multiple users within th