AMX Current Sensors PCS Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Vernetzung AMX Current Sensors PCS herunter. AMX Current Sensors PCS Instruction manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Integrated Axcess Controllers

instruction manualAxcess Central ControllersAxcent3 and Axcent3 ProIntegrated Axcess Controllers

Seite 2

Installation6Axcent3 and Axcent3 Pro Integrated Axcess ControllersRS-232/RS-422/RS-485 connectionsFIG. 4 shows the RS-232/RS-422/RS-485 DB-9 (male) co

Seite 3 - Table of Contents

Installation7Axcent3 and Axcent3 Pro Integrated Axcess ControllersGND wire on the AXlink/PWR connector when using a separate 12 VDC power supply. Do n

Seite 4

Installation8Axcent3 and Axcent3 Pro Integrated Axcess ControllersProgram connector (front and rear panels)Connect a programming cable to the PROGRAM

Seite 5 - Product Information

Axcess Programming9Axcent3 and Axcent3 Pro Integrated Axcess ControllersAxcess ProgrammingDevice and Channel NumbersThe following table lists the port

Seite 6 - Specifications (Cont.)

Axcess Programming10Axcent3 and Axcent3 Pro Integrated Axcess ControllersSend_Commands for RS-232/422/485 Mode (Cont.)CTSPSHEnables Pushes, Releases,

Seite 7 - Installation

Axcess Programming11Axcent3 and Axcent3 Pro Integrated Axcess ControllersSend_String Escape Sequences for RS-232/422/485 PortsThe table below lists th

Seite 8

Axcess Programming12Axcent3 and Axcent3 Pro Integrated Axcess ControllersSend_Commands for the IR/Serial/Data Ports (Cont.)CHGenerates IR digit pulses

Seite 9 - Wiring the Axcent

Axcess Programming13Axcent3 and Axcent3 Pro Integrated Axcess ControllersSend_Commands for the IR/Serial/Data Ports (Cont.)CTONSets the IR pulse (sing

Seite 10

Axcess Programming14Axcent3 and Axcent3 Pro Integrated Axcess ControllersSend_Commands for the IR/Serial/Data Ports (Cont.)PTOFSets IR power-off pulse

Seite 11 - 5 4 3 2 1

Axcess Programming15Axcent3 and Axcent3 Pro Integrated Axcess ControllersSend_Commands for the IR/Serial/Data Ports (Cont.)SPGenerates a single <IR

Seite 12 - Programming Unit

AMX Limited Warranty and DisclaimerAMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three

Seite 13 - Axcess Programming

Axcess Programming16Axcent3 and Axcent3 Pro Integrated Axcess ControllersSend_Commands for Input/Output PortsThe table below lists the I/O Send_Comman

Seite 14

Axcess Programming17Axcent3 and Axcent3 Pro Integrated Axcess ControllersStandard IR Function OrderThe table below lists the standard function order f

Seite 15 - ’CAROFF’

Axcess Programming18Axcent3 and Axcent3 Pro Integrated Axcess ControllersProgram Port CommandsThe PROGRAM port commands listed in the table below perf

Seite 16

Axcess Programming19Axcent3 and Axcent3 Pro Integrated Axcess ControllersPROGRAM Port Commands (Cont.)OFF Master Turns the device and channel numbers

Seite 17

Axcess Programming20Axcent3 and Axcent3 Pro Integrated Axcess ControllersPROGRAM Port Commands (Cont.)SET BASE DEVICE NUMBERMaster and SlaveSets the A

Seite 18

Axcess Programming21Axcent3 and Axcent3 Pro Integrated Axcess ControllersXmodem Timing CommandsThe table below lists the Axcent3 and Axcent3 Pro Xmode

Seite 19

Axcess Programming22Axcent3 and Axcent3 Pro Integrated Axcess Controllers6. Press ENTER four times to lock-in the communication settings. Now, you can

Seite 20

Axcess Programming23Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Seite 21 - Standard IR Function Order

Axcess Programming24Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Seite 22 - PROGRAM Port Commands

Replacing the Lithium Batteries25Axcent3 and Axcent3 Pro Integrated Axcess ControllersReplacing the Lithium BatteriesThere are two lithium batteries o

Seite 23 - PROGRAM Port Commands (Cont.)

Table of ContentsiAxcent3 and Axcent3 Pro Integrated Axcess ControllersTable of ContentsProduct Information ...

Seite 24

Replacing the Lithium Batteries26Axcent3 and Axcent3 Pro Integrated Axcess Controllers6. Carefully push the lithium battery, located in position B2, o

Seite 25

Updating Firmware27Axcent3 and Axcent3 Pro Integrated Axcess ControllersUpdating FirmwareThis section describes how to update the firmware in the cont

Seite 26 - Controller’s

Updating Firmware28Axcent3 and Axcent3 Pro Integrated Axcess ControllersFirmware can be downloaded to multiple device numbers automatically. If multip

Seite 27 - and Axcent

Updating Firmware29Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Seite 28

AMX reserves the right to alter specifications without notice at any time.030-004-1590 9/05 ©2005 AMX Corporation. All rights reserved. AMX, the AMX

Seite 29

iiAxcent3 and Axcent3 Pro Integrated Axcess ControllersTable of Contents

Seite 30

Product Information1Axcent3 and Axcent3 Pro Integrated Axcess ControllersProduct InformationThe Axcent3 and Axcent3 Pro Integrated Axcess Controllers

Seite 31 - Updating Firmware

Product Information2Axcent3 and Axcent3 Pro Integrated Axcess ControllersSpecifications (Cont.)Rear Panel Components:RS-232/RS-422/RS-485 portsSix 9-p

Seite 32

Installation3Axcent3 and Axcent3 Pro Integrated Axcess ControllersInstallationInstalling Axcess Control Cards (Axcent3 Pro Only)To install Axcess Cont

Seite 33

Installation4Axcent3 and Axcent3 Pro Integrated Axcess Controllers4. Connect the data cables into the controller.5. Connect the power cable to the AXL

Seite 34 - Last Revision: 09/12/05

Installation5Axcent3 and Axcent3 Pro Integrated Axcess Controllers5. Align the bracket holes with the mounting brackets on the equipment rack. Then, s

Kommentare zu diesen Handbüchern

Keine Kommentare