TEK 1 Applications
V041908
TEKVOX, Inc. – 210.348.6565 –
www.tekvox.com San Antonio, TX 78232
10
IR Control
In some installations the display device only has IR control. For these types of installations the TEK 1 is not able
to communicate directly with the device. With a few add-on products the TEK 1 can monitor and control these
types of devices. Below are some suggested add-on type devices and how to use them with the TEK 1.
It may not be necessary to control the projector. The projector may already be controlled by an IR device. For
these installations all that is required is to determine if the projector is on or off by using only a power current
sensor.
By adding a power current sensor at the display device the TEK 1 can determine if the device is powered on.
Once the TEK 1 knows the device is on, the internal lamp and maintenance timers within the TEK 1 are
operable.
Power Current Sensor
AMX PCS
Display Devices PCS-02
To control the display device add a programmable RS-232 to IR. The TEK 1 can then be programmed to
communicate with the IR module.
Programmable RS-232 to IR module
Xantech RS232IR Module
For security monitoring use the TekSecurity cable and connect the Security connection to a ground connection
on the display device.
Features
Internal timers for Lamp, Maintenance, Monthly Usage, Total Usage and System Off
Detects cut cables for device security (Reports by Email)
Email Reports including Device Errors, Monthly Usage and Security Email
Allows for IR only controlled devices
Determines if the monitored device is actually powered on