What’s New in X-Series Controllers
6
What’s New in X-Series Controllers
New NetLinx Commands
RS232 FAULT COMMANDS: (PORTS 1-8)
IR TX FAULT COMMANDS: (PORTS 11-18)
PoE COMMANDS (PORT 24-27)
RS422/485 (Port 1, Port 5)
For the RS-232/422/485 ports a new parameter to the SET BAUD command is required to enable RS-422 mode. The
new commands to turn on 422/485 are:
When 422/485 are disabled, the port operates in 232 mode.
Note: To disable both 422 and 485 modes with one command, end the command with 422/485 Disable.
AxLink Power and Fault Commands
AxLink power can be shut off by command:
The device responds with:
AX FAULT: UPPER/LOWER
'SET FAULT DETECT ON' Enables fault detection on the port (default setting)
'SET FAULT DETECT OFF' Disables fault detection on the port
'CLEAR FAULT' Forces reset back to normal status
'GET FAULT' Responds with one of the following: 'DISABLED', 'NONE', or
'NO DEVICE'
'GET STATUS' Responds with either "STATUS: NORMAL" or "STATUS: FAULT"
'SET FAULT DETECT ON' Enables fault detection on the port (default setting)
'SET FAULT DETECT OFF' Disables fault detection on the port
'CLEAR FAULT' Forces reset back to normal status
'GET FAULT' Responds with one of the following: 'DISABLED', 'NONE', or
'NO DEVICE'
'GET STATUS' Responds with either "STATUS: NORMAL" or "STATUS: FAULT"
'SET FAULT DETECT ON' Enables fault detection on the port (default setting)
'SET FAULT DETECT OFF' Disables fault detection on the port
'GET FAULT' Responds with one of the following: 'DISABLED', 'NONE',
'UNDER-VOLTAGE / OVER-VOLTAGE', 'CURRENT OVERLOAD', 'LOAD
DISCONNECT', 'MAX POWER EXCEEDED', or 'POE NOT AVAILABLE'
'GET STATUS' Responds with either "STATUS: NORMAL" or "STATUS: FAULT"
'SET POWER ON' Enables PoE to the port (default)
'SET POWER OFF' Disables PoE to the port
'GET CLASS' Responds with either 'DISABLED', 'NO DEVICE', or 'CLASS x
DEVICE' (x=0 to 4)
'GET VOLTAGE' Responds with number in Volts (typically this is around 55
Volts)
'GET CURRENT' Responds with number in milliAmps
’SET BAUD <baud>,<parity>,<data>,<stop>,[422<ENABLE | DISABLE>]’
’SET BAUD <baud>,<parity>,<data>,<stop>,[485<ENABLE | DISABLE>]’
’TSET BAUD <baud>,<parity>,<data>,<stop>,[422<ENABLE | DISABLE>]’
’TSET BAUD <baud>,<parity>,<data>,<stop>,[485<ENABLE | DISABLE>]’
‘AXPWRON [LOWER/UPPER]’
‘AXPWROFF [LOWER/UPPER]’
‘GET AX FAULT’