Troubleshooting
19
T10-PLV Single Camera Pan/Tilt System
Troubleshooting
If you are experiencing communication problems with the AXB-EM232, check the
communications settings for the device. The RS-232 communication parameters for this device are
set via the eight-position RS-232 DIP switch. On the AXB-EM232, the RS-232 DIP switch is
located on the front panel. Verify that this DIP switch is set to the default positions indicated in
below.
Setting the RS-232 DIP switch (S2)
This describes the RS-232 DIP switch default positions:
The following table lists the RS-232 DIP switch settings:
• 9,600 baud
• No parity
•8 bits
• 1 stop bit
RS-232 DIP Switch (S2) Settings
Position1 2 3456 7 8
Function Stop Bits Data Bits Parity Baud Rate
Off Off Off Off Off Off Off Off
2 bits 7 bits Unused 300
On On On Off Off On Off Off
1 bit 8 bits Unused 600
Off On Off Off On Off
Unused 1,200
On On Off On On Off
Unused 2,400
Off Off On Off Off On
Unused 4,800
On Off On On Off On
Even 9,600
Off On On Off On On
Odd 19,200
On On On On On On
None 38,400