No entry delay in HOME: When enabled, this option will cause the exterior delay zones to become instant when
the system is armed to HOME.
Auto. EML/LTM clear: All selected alerts that are sent to Event Memory Log and Long Term Memory are
cleared every 96 hours.
Zone trouble activation: This option applies only to supervised zones. With this option enabled, all trouble
conditions are treated as an activation when the system is armed.
System Options - Group 3
Signal end of exit delay: With this option, the system will speak "EXIT IS OVER" when the exit delay time has
expired after arming. The system will also speak "EXIT IN (number of seconds
remaining in exit delay)" every 10 seconds. NOTE: Exit delays greater than 90 seconds
are not enunciated until 90 seconds remain in the exit countdown.
Track activations: With this option enabled, each individual zone activation will be written to long term
memory as opposed to only the zone activation that created the alarm. For example,
the back door causes an activation, then a passive infrared zone detects motion and
then the front door opens. With this option enabled all of the activations will be written
to memory versus only the back door. In addition, as each zone is violated the speech
driver will speak the most recent zone violated as opposed to only the initial zone.
Regardless how this option is programmed, each zone will be reported to the central
station.
Voice driver: With this option selected, output to the speakers will alternate between siren tones and
speech when there is a fire, burglary, emergency or panic activation. The system will
say "FIRE, FIRE, REMAIN CALM, LEAVE IMMEDIATELY", "INTRUSION DETECTED,
INTRUSION DETECTED", and "ALERT, ALERT". Not only will the type of activation be
spoken, but also the description of the zone that caused it.
Enable split arming: The system can be divided into up to eight separate areas. Each zone is assigned to an
area and each user code is assigned an area or multiple areas. With this option
selected, the system will automatically require an access code before arming.
Openings and closings can be reported by user. The 001 and 002 force arm bypass
options in location 0243 are not available when using split arming. Night mode is not
available in split arming. When automatic arming and/or disarming is programmed, the
system will look to user code 32 to see which areas are to be armed and/or disarmed.
Split arming is not permitted in a UL installation.
Echo local phone speech: When local (in house) phones are used as keypads, system speech is typically only
heard through the phone. With this option selected, system speech will be heard
through the inside speaker as well as the phone.
Enable Night mode: With this option selected, the system can be placed into Night mode. When the system
is armed to HOME, press the H or # key. When armed to Night mode, both the AWAY
and HOME LED's on the keypad will be lit, the entry delay doors become instant and
interior delay #2 zones are active. To exit Night mode, disarm or press the H or # key to
return to HOME mode. Night mode is not available if split arming is enabled.