Inspired XPress - Programming Guide
4. Enter the Command Name in the appropriate field (FIG. 117) and select the Type of data to be accepted (Text or
Hex).
5. Below the Command Name and Command Text fields are 33 buttons, signifying common commands. Depending
upon whether you selected Text or Hex, clicking any of these buttons will enter the appropriate command text into
the Command Text field. Since the On and Off commands are not within these buttons, they must be entered
manually:
6. When finished entering the Command text, click Save Command. The new command appears in the Edit Variable
pane (FIG. 118);
If you press Next without entering a variable name, the page will display “Invalid
Command Name”.
FIG. 117 Edit Variable panel
Manual Command Text Entries:
Command Name Command Text (Text) Command Text (Hex)
On ka 00 01$0D; 6b612030302030310D
Off ka 00 00$0D; 6b612030302030300D