6. Daylight Savings Time - The system will automatically apply daylight savings time to your timers if
“Automatically adjust clock for daylight saving changes” is selected on your PC’s Date and Time
properties.
Bug Fixes
1. When a CC-16 or CC-64’s assignment is changed by invoking a parameter set, the settings of the
object are no longer changed but instead synchronize to the current value.
2. The EDR cards were not supported correctly in V1.101, this has been resolved.
3. CC-16 default min setting has been changed from -37 to -60dB and the default maximum setting is
changed from 0 to +12dB. This makes the CC-16 default settings the same as the CC-64.
4. Upload errors caused by characters such as ‘&’, ‘/, ‘<LF>’, ‘,’, ‘>’ and ’<’ have been fixed.
5. An issue where the DSP Resources button caused an error message if a parameter set's label ended
with double quotation mark has been fixed.
6. Some previous version files failed to open if a floating point value had been entered in a crossover.
This has been fixed.
7. An exception error caused when all modules in the ESP view were selected, copied, and then pasted
into another ESP has been fixed.
8. Preset and parameter set names can now accept ',' (comma).
9. Control of groups of input or output modules that span multiple ESPs has been fixed.
10. The CC-64 could not display labels with "&". This has been fixed.
11. The output connector of an output module can no longer be connected other modules.
12. An issue where the CC-64 smart simulator did not correctly update displayed gain values after
dynamic reprogramming has been fixed.
13. Various upload issues have been fixed
14. An issue with configurations that included groups stored in parameter sets that spanned multiple
ESPs has been resolved.
15. An issue with configurations that included groups of input/output modules stored in parameter sets
has been resolved.
16. An issue where “Bypass all” for a grouped PEQ did not synchronize to the other PEQs in the group
has been fixed.
17. PEQ settings from v1.001 will now import properly.
18. Bug fixed that incorrectly allowed a group of meters to be created.
19. Version 1.1 prohibited the CC-16 & CC-64 lock parameter from being added to a parameter set. This