AMX AXD-CP4/PB Spezifikationen Seite 74

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 364
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 73
EM - 18 Electronic Modules Ver. 0002
EM.2.2 DERATING OF THE MODULAR DRIVES
The following graphs show the maximum rms current in continuous duty cycle that the various
Drive modules can provide depending on ambient temperature.
Axis drives:
For a maximum time period of
0.5 seconds, and always in cycles longer than 10
seconds, they may output twice the current.
The AXD 1.08 and AXD 1.15 models, maintain their best characteristics, indicated in the
previous table, throughout the full temperature range, between 5 and 55°C (41 ºF and 131 ºF).
AXD 1.25 AXD 1.35
17
°C (°F)
Current
S1 (Amp)
50 (122)
17.5
55 (131)
10.2
°C (°F)
Current
S1 (Amp)
40 (104)
12.5
55 (131)
35 (95)
12
AXD 2.50
22
°C (°F)
Current
S1 (Amp)
40 (104)
25
55 (131)
AXD 2.75
25
°C (°F)
Current
S1 (Amp)
40 (104)
37.5
55 (131)
20 (68)
29.5
AXD 3.100
45
°C (°F)
Current
S1 (Amp)
45 (113)
50
55 (131)
AXD 3.150
68.5
°C (°F)
Current
S1 (Amp)
45 (113)
75
55 (131)
Seitenansicht 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 363 364

Kommentare zu diesen Handbüchern

Keine Kommentare