
Terminal (Program Port/Telnet) Commands
104
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
Terminal Commands (Cont.)
Command Description
SET ICSP TCP TIMEOUT Sets the timeout period for ICSP and i!-Web Control TCP connections.
Note: The new timeout value is immediately (no reboot required).
Example:
>SET ICSP TCP TIMEOUT
This will set the timeout for TCP connections for both ICSP
and i!-Web Control.When no communication has been detected
for the specified number of seconds, the socket connection is
closed.ICSP and i!-Web Control have built-in timeouts and
reducing the TCP timeout below these will cause undesirable
results. The default value is 45 seconds.
The current ICSP TCP timeout is 45 seconds
Enter new timeout (in seconds):
Once you enter a value and press the ENTER key, you get the
following message:
New timeout value set (in affect immediately).
SET IP <D:P:S> Sets the IP configuration of a specified device.
Enter a Host Name, Type (DHCP or Fixed), IP Address, Subnet Mask,
and Gateway IP Address.
Note: For NetLinx Central Controllers, the "Host Name" can only
consist of alphanumeric characters.
• Enter Y (yes) to approve/store the information into the Master.
• Enter N (no) to cancel the operation.
Note: The Device must be rebooted to enable new settings.
Example:
>SET IP [0:1:0]
--- Enter New Values or just hit Enter to keep current
settings ---
Enter Host Name: MLK_INSTRUCTOR
Enter IP type. Type D for DHCP or S for Static IP and then
Enter: DHCP
Enter Gateway IP: 192.168.21.2
You have entered: Host Name MLK_INSTRUCTOR
Type DHCP
Gateway IP 192.168.21.2
Is this correct? Type Y or N and Enter -> y
Settings written. Device must be rebooted to enable new
settings.
SET LOG COUNT Sets the number of entries allowed in the message log.
Note: The Master must be rebooted to enable new settings.
Example:
>SET LOG COUNT
Current log count = 1000
Enter new log count (between 50-10000):
Once you enter a value and press the ENTER key, you get the
following message:
Setting log count to
New log count set, reboot the Master for the change to
take affect.
Kommentare zu diesen Handbüchern