Initial Configuration and Firmware Upgrade
20
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3)
Resetting the Factory Default System and Device Values
1. In NetLinx Studio, access the Device Addressing dialog (FIG. 4 on page 6) by either one of these two
methods:
Right-click on any system device listed in the Workspace and select Device Addressing.
Select Diagnostics > Device Addressing from the Main menu.
2. Click the Set Device/System to Factory Default button. This resets both the system value and device
addresses (for definable devices) to their factory default settings. The system information (in the OnLine
Tree tab of the Workspace window) refreshes and then displays the new information.
3. Click Done to close the Device Addressing dialog.
4. Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master to
reboot.
The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait until
the STATUS LED is the only LED to blink.
5. Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.
6. Click the OnLine Tree tab in the Workspace window to view the devices on the System.
The default System value is one (1).
7. Right-click the associated System number (or anywhere within the tab itself) and select Refresh System.
This establishes a new connection to the specified System and populates the list with devices on that
system.
8. Use Ctrl+S to save these changes to your NetLinx Project.
By setting the system to its default value (#1), Modero panels that were set to
connect to the Master on another System value will not appear in the OnLine Tree
tab of the Workspace window.
For example: A Modero touch panel was previously set to System #2. The system is
then reset to its default setting of System #1 and then refreshed from within the
Workspace window. The panel will not reappear until the system is changed (from
within the System Connection page on the Modero) to match the new value and both
the Master and panel are rebooted.