OFPC Project No. 703-039 M.D. ANDERSON CANCER CENTER
Ambulatory Clinical Building
55050.00
AV BID AUDIO VISUAL SYSTEM
03/11/04 11738 -11
a maximum of 3-inches from the finished ceiling plane. All loudspeaker hardware to be new.
Coordinate exact location of loudspeaker conduit prior to conduit installation to minimize exposed cable
and rework above ceiling. Paint metal grill, enclosure, mounting hardware, and exposed cabling as
necessary to minimize visibility. Remove or paint all logos. Provide new and integrate into system as
shown in drawings.
LOUDSPEAKER VERTICAL ANGLE
(DEGREES)
HORIZONTAL ANGLE
(DEGREES)
ROTATION
(DEGREES)
LS-1 -57 62 0
LS-2 -61 0 0
LS-3 -57 -62 0
LS-4 -28 58 0
LS-5 -44 0 0
LS-6 -28 -58 0
K. Wall Mounted Control System Touch Panel (WCP-1) – AMX AXD-CP4/A 4-inch color passive touch
panel with 6 fixed external backlit illuminated pushbuttons (quantity: 2). Owner and AV Contractor to
coordinate all touch panel layouts. Program each panel to provide simple, intuitive control of all video /
RGBHV source and destination routing assignments, audiovisual system power (including projector
power), and VCR transport functions. Include screen design and menu branching drawings in
submittals. Locate at wall plate WP-C. Provide new and integrate into system as shown in drawings.
L. Audience Microphone (M) – Crown PCC-170SW hardwired boundary microphone with programmable
membrane switch (quantity: 30). Provide separate logic sense cabling from each microphone to control
system. Microphone cables to be routed through legs in audience tables. Install new where shown on
drawings.
M. Plasma Feedback Monitor (MPM-1) – Zenith P50W38 50-inch plasma display (quantity: 1) for use as a
feedback monitor. Provide Extron SY-VGAM-RGBHVM 6-foot VGA to RGBHV BNC cable (quantity: 1),
and Extron RG6/SHR-1 BNC to BNC 6-foot cable (quantity: 1) with unit. Mount on Draper Aero Mobile
1450 stand and field cut extruded aluminum column to place top of plasma display at 36-inches AFF and
bottom of plasma dsiplay at approximately 7-inches AFF. Mount Extron IPL-T-S2 Ethernet to serial
control interface to optional stand base shelf. Provide new and integrate into system as shown in
drawings.
N. Connectors – Connectors to be of the quantity and type as required for proper and durable operation
and signal transmission of the electrical characteristics for associated circuitry. Microphone connectors:
3-conductor XLR type. Control panels: XLR type with number of conductors as required. Line level and
left/right audio connectors: tip/ring/sleeve 1/4” phone jacks with insulated bushings. Composite video
and RGBS connectors: BNC dual crimp 75 ohm Canare or accepted substitution. S-video: standard 4-
pin S-video mini-din.
O. Interconnect Wiring – Provide and install following cable as required for connections in all areas. Meet
provisions of N.E.C.
Audio Plenum Rated Cable: West Penn 25452, West Penn 25291, or similar.