AMX MET-7 Spezifikationen Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 84
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
Custom Button Installation
9
Metreau Keypads
Custom Button Installation
Overview
With the exception of the DAS-MET-NUM, all Metreau keypads feature field-replaceable pre-printed buttons.
This section describes removing the original set of buttons and replacing them with custom buttons. FIG. 10
provides an exploded view of the keypad assembly.
Removing Buttons
The easiest way to remove and replace buttons on the Metreau keypads is to place the keypad assembly
(FIG. 10) face-down on a flat level surface, so that the buttons stay in position until you are ready to remove
them.
The Faceplate is attached to the Mounting Plate via four plastic tabs (two on each side of the Faceplate, as
shown in FIG. 10). It is not necessary to remove the plastic faceplate from the Mounting Plate in order to
replace buttons.
FIG. 1 Metreau keypads - Exploded view
Plastic Faceplate
Metal Mounting Plate
Buttons
Circuit board
tabs (2 on each side)
remove screw
remove screw
remove screw
remove screw
Disconnect the power supply and all wiring connections before removing/replacing
buttons on the Metreau keypads.
Before touching the device, discharge the static electricity from your body by touching
a grounded metal object.
Seitenansicht 16