Programming The Metreau Keypads
30
Metreau Keypads
LED Feedback for 2-Position Pushbuttons
The MET-7 and MET-13 Keypads feature a 2-Position pushbutton at the bottom of the button layout (FIG. 32).
It can be used either as a single button (in which case it functions just like the other buttons), or it can be used
as a 2-position button. In many cases, this button is used as a 2-Position button to provide ramp up/down
control, for volume, light levels, etc.
On the MET-7, the 2-Position button utilizes button numbers 7 (left-side) and 8 (right-side).
On the MET-13, the 2-Position button utilizes button numbers 13 (left-side) and 14 (right-side).
Only the left button provides LED feedback.
In order to achieve LED feedback on the right button, feedback must be toggled on the left button
Sending Firmware to Metreau Keypads (AxLink)
The Firmware on the AxLink-enabled Metreau keypads (MET-6N, MET-7 and MET-13) can be updated via
the NetLinx Studio2 application.
Device Addressing on MET-6N Keypads
The MET-6N uses two AxLink devices addresses - one for the Keypad itself, and a second one for
the IR Receiver.
The device address of the IR Receiver is auto-assigned to be one number higher than the device
address of the Keypad itself (to which the firmware is uploaded).
The MET-6N will appear as two devices in the Devices frame, because its built-in IR Receiver is
recognized as a separate online device.
Firmware is uploaded to the device address of the Keypad (not the IR Receiver).
For example, if the MET-6N is set to device address 127, then the IR Receiver on that
MET-6N will appear as device number 128. Firmware must be sent to the keypad, not the IR
Receiver (in this example, device 127).
1. Open NetLinx Studio2.
2. Go to Tools > Firmware Transfers > Send to Axcess Device... This opens the Send to Axcess Dialog
Window.
FIG. 3 MET-7 and MET-13 with 2-Position Button
MET-7 MET-13
Button #7
Button #8
Button #13
Button #14
Refer to the NetLinx Studio 2 online help for additional details on firmware transfers.