Seitenansicht 114
NetLinx Programming
113
TPI-PRO/DVI (Total Presentation Interface)
"^" Button Commands (Cont.)
^GRD
Change the bar-
graph ramp-down
time in 1/10th of a
second.
Syntax:
"'^GRD-<vt addr range>,<bargraph ramp down time>'"
Variables:
variable text address range = 1 - 4000.
bargraph ramp down time = in 1/10th of a second intervals.
Example:
SEND_COMMAND Panel,"'^GRD-500,200'"
Changes the bargraph ramp down time to 20 seconds.
^GRU
Change the bar-
graph ramp-up
time in 1/10th of a
second.
Syntax:
"'^GRU-<vt addr range>,<bargraph ramp up time>'"
Variable:
variable text address range = 1 - 4000.
bargraph ramp up time = in 1/10th of a second intervals.
Example:
SEND_COMMAND Panel,"'^GRU-500,100'"
Changes the bargraph ramp up time to 10 seconds.
^GSC
Change the bar-
graph slider color
or joystick cursor
color.
Note: You can also assign the color by color index, name, and R,G,B value (RRGGBB or
RRGGBBAA).
Syntax:
"'^GSC-<vt addr range>,<color value>'"
Variables:
variable text address range = 1 - 4000.
color value = Refer to theRGB Triplets And Names For Basic 88 Colors section on
page 88 for more information.
Example:
SEND_COMMAND Panel,"'^GSC-500,12'"
Changes the bargraph or joystick slider color to Yellow.