Wiring and Device Connections
17
TPI-PRO (Total Presentation Interface)
12VDC PWR (Power) Connector
The TPI-PRO requires a 12 VDC-compliant power supply to provide power to the TPI-PRO via the 2-pin 3.5
mm mini-Phoenix PWR connector (FIG. 19).
To use the 2-pin 3.5 mm mini-Phoenix connector for use with a 12 VDC-compliant power supply, the
incoming PWR and GND wires from the external power supply must be connected to their corresponding
locations on the connector (FIG. 20).
Constant current draw: 2.6 A @ 12 VDC
The PSN6.5 Power Supply (FG423-40 - not included) is recommended, to accommodate all
possible configurations and respective power draws.
FIG. 19 12VDC PWR (Power) Connector
12VDC PWR Power Connector
The TPI-PRO will power ON when the power supply is connected. Once power is
applied, use the Power button to toggle the unit off and on.
Do not connect power to the TPI-PRO until wiring is complete.
These units should only have one source of incoming power.
Using more than source of power to the panel can result in damage to the internal
components and a possible burn out.
Apply power to the panels only after installation is complete.
FIG. 20 NetLinx power connector wiring diagram
PWR +
GND -
TPI-PRO Power Supply
+
-
Never pre-tin wires for compression-type connections.