Programming the CCD-W6BRL Clear Connect Keypad
21
RPM Device Configuration Guide - NXB-CCG NetLinx Clear Connect Gateway
Note that the default (Dimmer) Level setting for all buttons is 100% (all on).
6. Optionally, click in the Fade cell to edit the Fade value (in seconds). Note that the default Fade setting for all
buttons is 2.00 s (2 seconds).
7. Click Save to save changes.
8. Repeat steps 1-6 for Buttons 2, 3, 4, 5 and 6 (i.e. select and configure "Button 2" under CCT Processor, then repeat
for Buttons 3-6):
9. Select the Button press will send press/release events for integration option (FIG. 57), only if you intend to
assign an RPM Macro to this button: :
By default, this option is de-selected.
Note that if you associate an RPM Macro with this button, then pressing this button will activate the Lighting
Scene, as well as trigger the Macro. See the Assigning Lighting Scenes to Macros section on page 27 for
details on working with Macros in RPM.
Once a Dimmer has been configured for Buttons 1 - 6, the dim (and fade) value specified for each Button will be
activated via the Keypad.
10. Add Switches to Buttons 1-6 as necessary. See Configuring Buttons 1-6: Adding Switch Functions section on
page 16 for details.
11. Click on Lower Button (under Keypad in the Devices window) to open the Lower Button Details page.
12. Click Add Device to open the Add Devices To a Button popup. Note that for Lower Button and Raise Button, the
only option is Dimmer (FIG. 58): .
13. Click Add to add the Dimmer to the Lower Button. This action closes the popup and adds the Device
Programming table to the Lower Button Details page (FIG. 59):
The Device Programming table consists of three columns:
14. Click on Raise Button (under Keypad in the Devices window) to open the Raise Button Details page.
FIG. 56 Dimmer Programming table - Editing the Level value
FIG. 57 Dimmer Programming - select
FIG. 58 Add Devices To a Button popup (for Lower Button and Raise Buttons)
FIG. 59 Lower Button Details page - Device Programming table
Device Name: The name of the device (Dimmer). The Device Name is read-only.
•Action: This is the ramp action (Lower) for the Lower Button (read-only).
Remove: Click to remove the Action from the Lower Button.