KI-1856C Rauland RANGER
®
Head End—
Installation
Page 11 of 55 (Jun-98)
Installation
Setting the Card Server Card(s) (
CS
)
Note: Discharge
static electricity
from your clothes
or body before
handling the
RANCPU
card.
Touch a metal
surface to ground
yourself or use a
grounding strap.
1.
If you have not already done so, mount the
RANCC16
(s) into the rack.
2.
If it is not already off, remove the front panel of the
RANCC16
by loosening the four
small thumbscrews.
3.
If you have not already done so, remove the
CS
card(s) from the
RANCC16
(s).
4.
If your system has multiple
RANCC16
s, set the
DIP
switches on the
CS
card(s) to the
settings detailed in Table 2 (or verify that the current settings match). As systems can
have multiple
RANCC16
s to support additional controllable resources (beyond 16), it
is critical that each card cage have a unique set of addressable slots. These should start
at 1 and continue sequentially. The table that follows shows how to set up the server
cards to address
RAN232, RANDTMF, RANRELAY8
or
RANIR
cards with addresses
above 16.
5.
Slide the
CS
card between the upper and lower white guides on the
RANCC16
slot
labeled “
CS”
until it snaps into place.
6.
Now you can load other control cards (
RANIR
,
RAN232, RANDTMF and RANRELAY8
).
7.
Secure the front panel of the unit.
8.
Connect the 18-gage red wire to the power supply's (e.g.,
RANPS
12) positive terminal
and the black wire to the negative terminal.
9.
Connect the other ends of the 18-gage wires to the
RANCC16
's “Pwr 12
VDC
Nom”
connector (two-pin plug or two-screw terminal strip) located on the unit's back. Be sure
to connect the red wire to the positive side of the connector and the black wire to the
negative side (see the silk screening on the back of the unit for proper locations).
10.
If there is more than one
RANCC
16, you may daisy-chain the power leads as well as
the
AxL
ink “
GND
,” “
AXP,”
and “
AXM”
connections.