Page 20 of 55 (Jun-98)
and grouping classrooms so that no output exceeds 50,000 pF of capacitance. The
following table specifies the allowed distances:
Table 9. Maximum Cable Distances per run of
RANBROAD
Cable
Capacitance
(per foot)
Maximum Cumulative
Distance (in feet)
WP D291 26 2300
WP 291 45 1200
WP D2401 14.5 4000
WP D252401
(Plenum)
14.5 4000
Belden 8102 12.5 4500
The “To
CPU
” terminal of the first
RANBROAD
is generally connected to Com 2 of the
RANPCSW
Media Center. This port is used for Control System maintenance, such as
downloading Control Code, changing the Send Panel Program, and sending IR codes.
The “
RS
232 In” and “
RS
232 Out” male
DB
9 connectors are used to allow the control-
link pseudo
RS
485 signal to be converted to
RS
232, travel via fiber or dedicated
modem, etc. The data rate is 19.2 kb. However, the data structure does not follow
conventional asynchronous formats such as those used by
PC
s. The
RS
232 Out”
originates with the first
RANBROAD
, which contains the
RANCPU
, and is connected to
the
RS
232 In” connector on the second
RANBROAD
. In like manner, the second
RANBROAD
’s “
RS
232 Out” connector can be connected to a third
RANBROAD
’s
RS
232 In” connector. At this time it is not known how many layers deep this can go.
The pinouts of these connectors follow:
Table 10.
Pin Number
RS
232 Out
RS
232 In Comments
1
LED
(out)
LED
(in)
Flashes “
CPU
Active”
LED
on front (optional)
2 RxD (in) TxD (out) Required
3 TxD (out) RxD (in) Required
4
DTR
(out)
DTR
(in) Required
5
GND GND
Required
If the units are in the same rack, wire them together by connecting Pin 1 to Pin 1, Pin 2
to Pin 2, etc. If the units are more than 50 feet apart, connect Pins 1–5 . to the
appropriate pins on the
RS
232 fiber transceiver or modem. The pinouts of the standard
DB
9 and
DB
25 connectors used in these devices follow: