KI-1856C Rauland RANGER
®
Head End—
Installation
Page 14 of 55 (Jun-98)
Installation
Note: Discharge
static electricity from
your clothes or body
before handling the
RANCPU
card.
Touch a metal
surface to ground
yourself or use a
grounding strap.
1.
If you have not already done so, mount the
RANCC16
(s) into the rack.
2.
If it is not already off, remove the front panel of the
RANCC
16 by loosening the fou
small thumbscrews.
3.
If you have not already done so, remove the
CS
card(s) from the
RANCC
16(s).
4.
If your system has multiple
RANCC
16s, set the
DIP
switches on the
CS
card(s) to the
settings detailed in Table 2 (or verify that the current settings match). As systems can
have multiple
RANCC
16s to support additional controllable resources (beyond 16), i
is critical that each card cage have a unique set of addressable slots. The table that
follows shows how to set up the server cards to address
RAN
232 or
RANIR
cards wit
addresses above 16.
Setting the
RANCPU
's
DIP
Switches
1.
If you have not already done so, remove the
RANCPU
from the
RANCC16
. You will
find the card in the slot labeled “
MC1
.”
2.
The following illustration shows how to set the
RANCPU
's
DIP
switch settings to
38,400 baud, no parity, 1 stop bit, 8 data bits.
ON
81234 5 67
Figure 4. S1
DIP
Switch Settings.
3.
Slide the
RANCPU
card between the upper and lower white guides on the
RANCC16
slot labeled “
MC1
” until it snaps into place.
4.
Secure the front panel of the unit.